Samsung
Connection Diagrams
Samsung Self-diagnostic Malfunction (Error) Codes
Malfunction Code |
Content of Abnormality | Notes |
---|---|---|
101 | DVM,DPM,DVS:Outdoor Unit Communication Error (Indoor unit can’t receive communication) SINGLE: Indoor Unit Panel - Main communication error |
|
102 | Outdoor Unit to Indoor Unit communication error | |
103 | Communication Error Between Indoor Unit Panel and Main | |
104 | Communication Error | |
105 | Communication Error in between sensing space module and Indoor unit | |
106 | Communication Error Between LCD and Panel | |
107 | Communication Error Between LCD Outdoor Unit | |
108 | Error due to repeated address setting (When 2 or more devices has same address within the network) | |
109 | Communication error - indoor address is not completed. Check communication wire between indoor and
outdoor, outdoor unit quantity, indoor address setting status. |
|
121 | Error of ROOM Temperature Sensor in Indoor unit short/open | |
122 | Error of Evaporator_in Sensor of Indoor unit short/open | |
123 | Error of Evaporator_out Sensor of Indoor unit short/open | |
124 | Indoor Unit Communication Error (Indoor Unit /
Outdoor Unit Communication Error displayed in Outdoor unit) |
|
125 | Eva_mid2 Sensor of Indoor unit short/open | |
127 | Indoor Temperature (Suction Temperature) Sensor breakaway Error | |
128 | Breakaway of Indoor unit Evaporator_in Sensor | |
129 | Breakaway of Indoor unit Evaporator_out Sensor | |
130 | Breakaway of evaporator in and evaporator out sensors in indoor unit at the same time | |
131 | Sub(Electronic) Heater Sensor 1 Error | |
132 | Sub(Electronic) Heater Sensor 2 Error | |
133 | Sub(Electronic) Heater Sensor 3 Error | |
134 | Shutter Sensor Error (In case of model which have two shutter, upper Error : Aurora) | |
135 | Perfect Fan Sensor Error | |
136 | Shutter Sensor Error (In case, model which have two shutter Error in bottom : Aurora) | Aurora Bottom Sensor |
137 | VOC SENSOR OPEN/SHORT ERROR | |
138 | GAS SENSOR OPEN/SHORT ERROR | |
139 | ERV CO2 SENSOR OPEN/SHORT ERROR | |
140 | Indoor Dust sensor Error | |
141 | IAQ CO2 SENSOR OPEN/SHORT ERROR | |
142 | Indoor Unit Humid Sensor short/open | |
143 | Sensing space Sensor Error | |
144 | Eva2_in Sensor of Indoor Unit short/open | |
145 | Eva2_out Sensor of Indoor Unit short/open | |
146 | EEV Inlet Sensor short/open | |
147 | Indoor Eva2_in Sensor break away Error | |
148 | Indoor Eva2_out Sensor break away Error | |
149 | AHU Master Indoor room sensor setting error | |
150 | RESERVED(DMS-SNET3 Error) | |
151 | Open error of electoronic expansion valve in indoor unit(2nd) | Check MCU addressing if HR |
152 | Close error of electoronic expansion valve in indoor unit(2nd) | Check MCU addressing if HR |
153 | Dectect Indoor float s/w 2nd | |
154 | Indoor unit Fan Error | |
155 | Indoor unit Fan2 Error | |
156 | Indoor unit (EEV2) open error 2nd | |
157 | Indoor unit (EEV2) close error 2nd | |
158 | UDoor upper operation Error | (check Photo Sensor or operating Relay Error) |
159 | UDoor lower operation Error | (check Photo Sensor or operating Relay Error) |
161 | Cooling and Heating mixed operating Error | |
162 | Outdoor unit EEPROM error | |
163 | EEPROM OPTION SETTING ERROR | |
165 | Elect Discharge Temp Protect Error | |
166 | Electric motor related to no wind Error | |
167 | Unsing peripheral in Indoor Unit Option DIP S/W set Error | |
168 | IAQ Safety S/W Open Error | |
169 | AHU EEV Fault detection error | |
170 | Error; Fahrenheit /Celsius degree use same time (Indoor Unit which selected Celsius) | |
174 | ERV + heat exchanger inlet temperature sensor short / open | |
175 | Outdoor built-in indoor temperature sensor short / open error | |
177 | In hydro box, take place emergency signal Error | |
180 | MCU SOL Valve cooling/heating opening 1st at the same time | |
181 | MCU SOL Valve cooling/heating opening 1st at the same time | |
185 | Missconnect power line to Indoor Unit communication line | |
186 | sMPI(SPI) Feedback Error | |
187 | K1Filter Feedback Error | |
190 | While in checking pipe, no change Temp in Eva_in or change Temp Eva_in of other Indoor unit | |
191 | While in checking pipe, no change Temp in Eva_out or change Temp Eva_out of other Indoor unit | |
192 | Indoor Unit COVER OPEN (Indoor unit switch for safety) | |
193 | Indoor Panel Zero-Crossing Error | |
194 | Indoor Main Zero-Crossing Error | |
195 | IAQ safety S/W Open Error | |
198 | Error due to disconnected thermal fuse of indoor unit | |
199 | Error in Display Status of No pipe checking | |
201 | After complete Tracking 5 times, mismatch of the indoor unit quantity set with those
found by ODU error (some of indoor units disconnected communication wire, IDU powered off etc.) |
|
202 | System Down (All Indoor unit Short) due to Communication Error | |
203 | Outdoor Unit Communication Error Between MAIN-- SUB | |
204 | After completing Tracking 5 times, there is different with a number of set MCU and communicated MCU | |
205 | Communication Error on all PBA within the outdoor unit C-Box, communication cable error
Communication Error Between Outdoor Unit Inv Micom -- Fan Motor Micom |
|
206 | Communication Error Between Outdoor Unit Main PBA - Sub PBA | |
206-C001 | Communication Error Between Outdoor Unit Main PBA - Sub PBA | |
206-C002 | FAN PBA communication error | |
206-C003 | INV1 PBA communication error | |
206-C004 | INV2 PBA communication error | |
210 | Can NOT communicate with MCU over 2 min | |
211 | Indoor unit connected with confluence kit without continunity | |
212 | Indoor unit connected with confluence kit and setting address was overlapped more than 3 | |
213 | MCU address not matched with indoor unit address | |
214 | MCU address not matched with outdoor unit address | |
215 | Rotary switch for indoor unit address in MCU was over lapped among MCUs | |
216 | DIP switch for indoor unit setting was ON position even though indoor unit was not connected | |
217 | DIP switch for indoor unit setting was OFF position even though indoor unit was connected | |
218 | Setting number of indoor unit in MCU is larger than installed indoor units | |
219 | Error on temperature sensor located on MCU intercooler inlet (Short or Open)
MCU Over Cooling In Sensor Open/Short |
|
220 | Error on temperature sensor located on MCU intercooler outlet (Short or Open)
MCU Over Cooling Out Sensor Open/Short |
|
221 | OUT temperature SENSOR ERROR (OPEN/SHORT)
- ERROR LEVEL: more than 4.9V(-50oC), less than 0.4V(93oC) |
|
226 | OUT_temperature temperature Sensor breakaway Error | |
231 | COND_OUT Main temperature SENSOR ERROR (OPEN/SHORT)
- ERROR LEVEL: More than 4.9V(-50oC), less than 0.4V(93oC)” |
|
236 | COND_OUT Sub1 temperature SENSOR ERROR (OPEN/SHORT)
- ERROR LEVEL: More than 4.9V(-50oC), less 0.4V(93oC)” |
|
237 | COND temperature SENSOR ERROR (OPEN/SHORT)
- ERROR LEVEL: More than 4.9V(-50oC), less than 0.4V(93oC) |
|
241 | COND_MID or COND OUT Sensor of Outdoor Unit breakaway Error | |
242 | Outdoor Unit Heater Error | |
246 | COND_OUT 1 breakaway | |
251 | PWM DISCHARGE temperature SENSOR ERROR (OPEN/SHORT)
- ERROR detect Condition: detect Outdoor temperature more than -10oC - ERROR LEVEL: More than 4.95V(-30’C), less than 0.5V(151’C) |
|
256 | Fixed COMP 1 DCHRG SENSOR ERROR (OPEN/SHORT)
- ERROR detect Condition: detect Outdoor temperature more than - ERROR LEVEL: More than 4.95V(-30’C), less than 0.5V(151’C) |
|
257 | Fixed COMP 2 DCHRG SENSOR ERROR (OPEN/SHORT)
- ERROR detect Condition: detect Outdoor temperature more than -10oC - ERROR LEVEL: more than 4.95V(-30’C),less than 0.5V(151’C)” |
|
258 | Fixed COMP 3 DCHRG SENSOR ERROR (OPEN/SHORT)
- ERROR detect Condition: Outdoor temperature more than -10 detect oC - ERROR LEVEL: more than 4.95V(-30’C),less than 0.5V(151’C) |
|
261 | ||
262 | ||
263 | ||
264 | ||
265 | ||
266 | ||
267 | ||
268 | ||
269 | ||
212 | ||
213 | ||
214 | ||
215 | ||
216 | ||
217 | ||
218 | ||
219 | ||
220 | ||
211 | ||
212 | ||
213 | ||
214 | ||
215 | ||
216 | ||
217 | ||
218 | ||
219 | ||
220 |